Microlyzer SVF Kit

Microlyzer SVF Kit

Not injectable fat,

True SVF cell isolation...

True regenerative therapy...

Microlyzer SVF Kit offers you a system to obtain high mesenchymal stem cell counts without using enzymes. Moreover, it is much faster and with much smaller investment costs than enzymatic systems. Discover regenerative treatments now with T-LAB.

Videoyu oynat

NOT FAT TISSUE,
NON-ENZYMATIC,
REAL SVF CELL ISOLATION

NOT OIL, CELL ISOLATION

We do not call the process of making adipose tissue injectable as stem cells. We completely isolate the SVF cells from the tissue for you.

Our final product is rich in nucleated cell, while completely excluding fibrotic tissue, fat cell and triglyceride. We offer you safe injection with the 41 Micron filtering we apply to the final product.

NOT MECHANICAL,
REGENERATIVE EFFECT

Fat injection provides a mechanical effect in patients due to its nature, but it cannot create a high regenerative effect in terms of stem cells like concentrated SVF isolation.

Stem cells separated from the tissue and concentrated can multiply rapidly in the body in the natural nutrient medium and turn into different cells. It offers you a real regenerative treatment, unlike fat injection.

NOT TEXTURE,
COUNTABLE CELLS

Micronized adipose tissues also contain stem cells, but this does not mean that SVF cell groups are isolated and become pure and concentrated.

With Microlyzer SVF, you can see the final product with your own eyes under any microscope, even detect, count and easily measure the viability of nucleated/nucleated cells under a fluorescent microscope.

SVF_Kutu_01

LIPOASPIRATION

With the special degreasing syringe with locking mechanism, disposable cannula and sterile centrifuge godets and special decantation apparatus, degreasing has never been so comfortable.
SVF_Kutu_02

OIL PURIFICATION CONDENSING

4 special 10cc syringes become a tube with two movements and are ready for centrifugation. Moreover, a small centrifuge is enough for you.
SVF_Kutu_03

MICRONIZING

With Microlyzer's tissue technology, which is far superior to mesh and plastic filters, SVF cells are easily released.
SVF_Kutu_04

SVF CELL ISOLATION

With two 10ml special tubes and a long needle, the SVF layer is easily separated from the oil and collected. With its 41micron cell filter, it does not allow the passage of particles larger than the cell size.
Microlyzer SVF gives you visible evidence

Immediately after SVF Cell isolation
Counting and analysis results with a Fluorescent Microscope

[Total cell] : 4.24 x 107 cells/mL
[Nucleated cell] : 24.2 x 106 cells/mL
[Non-nucleated cell] : 1.89 x 107 cells/mL
Viability of nucleated cell : 92.8% 

*Obtained from samples dated December 28, 2020. Counting was done with the LunaSTEM device and the report of Asst. Assoc. Prof. Dr. Seher Üstün Yaylacı was used.

Not cultured,
Tresh insulation,
Flow Cytometry Data.

FITC: CD73      : %61,6
APC: CD90       : %81,2
PerCP: CD105  : %2,3

Flow Cytometry was used to differentiate between hematopoietic and endothelial cell populations and the exclusion of surface antigens (CD34, CD29, CD14, CD11b and HLA-DR) helped us to determine the percentage of mesenchymal, endothelial, pericyte, leukocyte, stromal/progenitor cells in the final product.

*The study on samples dated December 28, 2020 was conducted by Hacettepe University Teknokent Maia Health Consultancy. Counting results were obtained from the report of Asst. Assoc. Prof. Dr. Seher Üstün Yaylacı. Analyses were performed using BD FACSCantoll instrument and BD FACS Diva software.